The Pinnacles, Harlow,
Essex, CM19 5BD
Electronic
Postal Scale
N500 series
- UK Model N521 & N521P
Operating Guide
We have made every reasonable effort to assure the accuracy and usefulness of this
guide, however we cannot assume responsibility for errors or omissions or liability for the
misuse or misapplication of our products.
© Pitney Bowes Limited, 2002Form No. N572001 REV B (11-02) Printed in U.S.A.
FOR SERVICE AND SUPPLIES:
W
eight Hold
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - Operating Guide

The Pinnacles, Harlow,Essex, CM19 5BDElectronicPostal ScaleN500 series- UK Model N521 & N521POperating GuideWe have made every reasonable effort t

Pagina 2 - INTRODUCTION

9N500 User GuideCategory/Carrier KeysScroll KeysThese keys are either one-touch Category keys or Carrier keys. Pressinga Category key will act as a sh

Pagina 3 - PRECAUTIONS

10CHAPTER 2: USING YOUR SCALEThe following assumes you or a Pitney Bowes engineer have completedthe installation instructions included with your scale

Pagina 4 - Weight Hold

11N500 User GuideChoosing a Category0gSelect Category- Royal Mail- ParcelforceAccount:01Note: If your scaleis connected to ameter withaccountingactiva

Pagina 5 - WIRES, CABLES, &

12CHAPTER 2: USING YOUR SCALEChoosing FeesWhen a Category is selected and a price shown, the display will list thepermitted fees for the Category. You

Pagina 6 - GETTING HELP

13N500 User GuideYou can manually add any amount to the postage displayed. Use theAlpha-numeric keys to select the amount and then press the Enter key

Pagina 7 - CHAPTER 1: INTRODUCTION

14CHAPTER 2: USING YOUR SCALEUSING THEWEIGHT HOLDFEATURE The weight hold feature is useful when weighing large envelopes that block the display.

Pagina 8 - USING YOUR SCALE

15N500 User GuideThis function allows you to generate multiple tapes to equal a postageamount greater than the printing capacity of the attached meter

Pagina 9

16CHAPTER 2: USING YOUR SCALEUSING ‘SCALEFUNCTIONS’FEATUREFee Recall13gScale Functions- Fee Recall- Weight Hold- Manual Weight Entry- Parts CountThe s

Pagina 10

17N500 User GuideNote: All like Itemsmust be the sameindividual weight.Pa r ts CountThis function allows you to obtain a count of items based on a sam

Pagina 11 - USING THE SCALE

18CHAPTER 2: USING YOUR SCALEMETER FUNCTIONSFunds13gMeter Functions- Funds- Account StatusIf the scale is linked to a PitneyBowes postage meter, you c

Pagina 12 - Choosing a Category

1CHAPTER 1INTRODUCTIONOffers a brief description of the scale and keypad, covers safetyprecautions, cabling, specifications, and help information.Abou

Pagina 13 - CHAPTER 2: USING YOUR SCALE

19N500 User GuideCHANGINGSETUP OPTIONSUser Setup- Exit- OFF Autoclear Cat- OFF Autoclear Zone- ON ClrZoneNewCat- OFF Auto Weigh Hold- Supervisor Setu

Pagina 14

20CHAPTER 2: USING YOUR SCALENote: Pressing Exitwhile in a supervisoroption returns youto the previousscreen.Default Option DescriptionOff Other Lang

Pagina 15 - WEIGHT HOLD

21CHAPTER 3TROUBLESHOOTINGClearing Error Messages ... 22Diagnosing Problems ...

Pagina 16 - Currency Breakdown

22CHAPTER 3: TROUBLESHOOTINGDIAGNOSINGPROBLEMSOccasionally, error messages display on the screen. Sometimes theyidentify an incorrect entry and indica

Pagina 17 - FUNCTIONS’

23N500 User GuideProbableSymptom Cause RecommendationBlank screen. A. Sleep mode. Touch the weight platform.B. PROM not firmly Reinstall/replace PROM.

Pagina 18 - Pa r ts Count

24CHAPTER 3: TROUBLESHOOTING

Pagina 19 - METER FUNCTIONS

25CHAPTER 4MAINTAINING YOUR SCALEIncludes cleaning instructions and how to install rate PROMs.Cleaning ...

Pagina 20 - SETUP OPTIONS

26CHAPTER 4: MAINTAINING YOUR SCALEYour scale requires very little maintenance. Simply keep it clean bywiping it with a soft dry cloth. Do not use har

Pagina 21

27N500 User Guide1. Tu rn power OFF at the walloutlet.2. Remove the platform bylifting straight upwards.3. Slide the old PROM out ofits location slot.

Pagina 22 - TROUBLESHOOTING

28CHAPTER 4: MAINTAINING YOUR SCALEPitney Bowes provides service throughout the UK.Should you require service or assistance call the Pitney BowesCAREL

Pagina 23 - MESSAGES

2CHAPTER 1: INTRODUCTIONThe N500 series Electronic Postal Scale is a 2kg capacity decisionmaking scale which uses computer technology to give you an a

Pagina 24 - Symptom Cause Recommendation

The Pinnacles, Harlow,Essex, CM19 5BDElectronicPostal ScaleN500 series- UK Model N521 & N521POperating GuideWe have made every reasonable effort t

Pagina 25 - CHAPTER 3: TROUBLESHOOTING

3N500 User GuideWeight HoldSCALE & KEYPADIDENTIFICATIONWeighing PlatformAdjustableFeet (4)LevelIndicatorRate PROM(Under Platform)DisplayColour Key

Pagina 26 - MAINTAINING YOUR SCALE

4CHAPTER 1: INTRODUCTION1CONNECTINGWIRES, CABLES, &METERYour scale should already have been installed, either by yourself or by aPitney Bowes engi

Pagina 27 - (PROM) CHANGE

5N500 User GuidePower supply: Input: 230VAC, 50HzOutput: 9VDC, 300mAPhysical dimensions: 271mm deep x 237mm wide x 75mm highWeight: 1.7kgOperating tem

Pagina 28 - Fitting the PROM

6CHAPTER 1: INTRODUCTION

Pagina 29

7CHAPTER 2USING YOUR SCALEThis Chapter describes the process of weighing a mailpiece andcalculating postage. It also provides information on special s

Pagina 30

8CHAPTER 2: USING YOUR SCALEWeight HoldThis section is intended to familiarise you with the keyboard. Fulldetails of all key functions will be covered